Limit Switch Z-15GW21-B Z15GW21B 15a lever 29mm screw Microswitch spdt

MICRO SWITCH SMALL LEVER

Actuator Short hinge lever
Contact form SPDT
Terminal Screw terminal (M4)
Rated current 15 A
Degree of protection IP00

Code: Z-15GW21-B

Category: Tags: ,
Actuator Short hinge lever
Stainless steel lever
Radius of curvature: R28.2
Contact form SPDT
Rivet
Ag
Contact gap (standard value) 0.5 mm
Terminal Screw terminal (M4)
Load General load
Rated current 15 A
Ratings (AC) Non-Inductive load Resistive load: 15 A at 125 VAC, 15 A at 250 VAC, 10 A at 500 VAC
Lamp load (NC): 3 A at 125 VAC, 2.5 A at 250 VAC, 1.5 A at 500 VAC
Lamp load (NO): 1.5 A at 125 VAC, 1.25 A at 250 VAC, 0.75 A at 500 VAC
Inductive load: 15 A at 125 VAC, 15 A at 250 VAC, 6 A at 500 VAC
Motor load (NC): 5 A at 125 VAC, 3 A at 250 VAC, 1.5 A at 500 VAC
Motor load (NO): 2.5 A at 125 VAC, 1.5 A at 250 VAC, 0.75 A at 500 VAC
Ratings (DC) Non-Inductive load Resistive load: 15 A at 8 VDC, 15 A at 14 VDC, 6 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Lamp load (NC): 3 A at 8 VDC, 3 A at 14 VDC, 3 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Lamp load (NO): 1.5 A at 8 VDC, 1.5 A at 14 VDC, 1.5 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Inductive load: 15 A at 8 VDC, 10 A at 14 VDC, 5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Motor load (NC): 5 A at 8 VDC, 5 A at 14 VDC, 5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Motor load (NO): 2.5 A at 8 VDC, 2.5 A at 14 VDC, 2.5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Inrush current NC: 30 A max.
NO: 15 A max.
Ambient temperature -25 to 80 ℃ (with no icing)
Ambient humidity 35 to 85% RH
 
Permissible operating frequency Electrical: 20 operations / 1 minute max.
Mechanical: 240 operations / 1 minute max.
Contact resistance (Initial value) 15 mΩ max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min
Between live-metallic part and ground: 2,000 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz 1 min
Durability Electrical: 500,000 operations min.
Mechanical: 10 million operations min.
Degree of protection IP00
Degree of protection against electric shock Class I
Proof tracking index(PTI) 175
 
Operating Force (OF) Standard value 1.57 N max.
Release Force (RF) Standard value 0.27 N min.
Over-Travel (OT) Standard value 2 mm min.
Movement Differential (MD) Standard value 1 mm max.
Free Position (FP) Standard value 24.8 mm max.
Operating Position (OP) Standard value 18.2 to 19.8 mm