H3Y-4 24V DC – 24 VDC, Output Time-limit: 4PDT, Power ON-delay, Time range: 0.1 to 3 h (1 range), 14-pin

TIMER 24V DC 60S

Rated power supply voltage 24 VDC If power supply incorporates a single-phase full-wave rectifier.
Control output (Type) Time-limit: 4PDT
Operating resetting Time-limit operation/Self-reset
Connecting method 14-pin round socket

Code: H3Y-4 24V DC

Category: Tags: , ,
Rated power supply voltage 24 VDC If power supply incorporates a single-phase full-wave rectifier.
Allowable voltage variable range 85 to 110% of the power supply voltage
Power consumption Approx. 0.9 W (at 24 VDC)
Reset voltage 10% min, of rated supply voltage
Number of time ranges 1
Operation mode Power ON-delay
Control output (Type) Time-limit: 4PDT
Control output (Contact output) Resistive load: 3 A at 250 VAC (cosφ=1)
Minimum applicable load: 1 mA at 1 VDC (failure level: P)
Operating resetting Time-limit operation/Self-reset
Ambient temperature range Operating: -10 to 50 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing)
Ambient humidity range Operating: 35 to 85%
Accuracy of operating time ±1% FS max.
Setting error ±10% FS ±50 ms max.
Reset time 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max.
Influence of temperature ±2% FS max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded)
Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 1,500 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltage Between power terminals: 1 kV
Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV
Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Mulfunction: 4 kV, Destruction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistance Destruction: 1,000 m/s2, 3 times each in 6 directions
Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output) Electrical: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h, Room temperature)
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Degree of protection IP40
Connecting method 14-pin round socket
Case color Beige
Weight Approx. 50 g

 

Outline drawing

Internal connection

Time ranges

Operating chart

Power ON-delay

Electrical life curve