Omron Z-15GQ21-B General Purpose Basic Switch, Panel Mount Cross Roller Plunger, Medium OP, Screw Terminal, 0.5mm Contact Gap, 15A Rated Current

MICRO SWITCH ROLLER BUTTON 90 Degrees

Actuator Panel mount cross roller plunger
Contact form SPDT
Terminal Screw terminal (M4)
Rated current 15 A
Degree of protection IP00

Code: Z-15GQ21-B

Category: Tags: , ,
Actuator Panel mount cross roller plunger 12.7 dia. x 4.8
Stainless steel roller
Contact form SPDT
Rivet
Ag
Contact gap (standard value) 0.5 mm
Terminal Screw terminal (M4)
Load General load
Rated current 15 A
Ratings (AC) Non-Inductive load Resistive load: 15 A at 125 VAC, 15 A at 250 VAC, 10 A at 500 VAC
Lamp load (NC): 3 A at 125 VAC, 2.5 A at 250 VAC, 1.5 A at 500 VAC
Lamp load (NO): 1.5 A at 125 VAC, 1.25 A at 250 VAC, 0.75 A at 500 VAC
Inductive load: 15 A at 125 VAC, 15 A at 250 VAC, 6 A at 500 VAC
Motor load (NC): 5 A at 125 VAC, 3 A at 250 VAC, 1.5 A at 500 VAC
Motor load (NO): 2.5 A at 125 VAC, 1.5 A at 250 VAC, 0.75 A at 500 VAC
Ratings (DC) Non-Inductive load Resistive load: 15 A at 8 VDC, 15 A at 14 VDC, 6 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Lamp load (NC): 3 A at 8 VDC, 3 A at 14 VDC, 3 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Lamp load (NO): 1.5 A at 8 VDC, 1.5 A at 14 VDC, 1.5 A at 30 VDC, 0.5 A at 125 VDC, 0.25 A at 250 VDC
Inductive load: 15 A at 8 VDC, 10 A at 14 VDC, 5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Motor load (NC): 5 A at 8 VDC, 5 A at 14 VDC, 5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Motor load (NO): 2.5 A at 8 VDC, 2.5 A at 14 VDC, 2.5 A at 30 VDC, 0.05 A at 125 VDC, 0.03 A at 250 VDC
Inrush current NC: 30 A max.
NO: 15 A max.
Ambient temperature -25 to 80 ℃ (with no icing)
Ambient humidity 35 to 85% RH
 
Speed of permissible operation 0.01 mm/s to 1 m/s
Permissible operating frequency Electrical: 20 operations / 1 minute max.
Mechanical: 240 operations / 1 minute max.
Contact resistance (Initial value) 15 mΩ max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min
Between live-metallic part and ground: 2,000 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz 1 min
Durability Electrical: 500,000 operations min.
Mechanical: 10 million operations min.
Degree of protection IP00
Degree of protection against electric shock Class I
Proof tracking index(PTI) 175
 
Operating Force (OF) Standard value 2.45 to 3.43 N
Release Force (RF) Standard value 1.12 N min.
Pre-Travel (PT) Standard value 0.4 mm max.
Over-Travel (OT) Standard value 3.58 mm min.
Movement Differential (MD) Standard value 0.05 mm max.
Operating Position (OP) Standard value 32.2 to 34.6 mm