Option input | CT, Digital(DI-1) |
---|---|
Option output | Alarm 1, Transmission(DC4-20mA) |
Power supply | 100-240VAC~ 50/60Hz |
Protection structure | IP65(front panel) |
Approval | |
Display accuracy_RTD | •At room temperature(23?±5?):(PV ±0.3% or ±1?, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2?, select the higher one) ±1-digit |
Display accuracy_Thermocouple | •At room temperature(23?±5?):(PV ±0.3% or ±1?, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2?, select the higher one) ±1-digit |
Display accuracy_Analog | •At room temperature(23?±5?): ±0.3% F.S. ±1-digit •Out of range of room temperature: ±0.5?% F.S. ±1-digit |
Display accuracy_CT input | ±5% F.S. ±1-digit |
Hysteresis(adjustable sensitivity) | RTD/Thermocouples: 1 to 100℃/℉(0.1 to 100.0℃/℉) variable Analog: 1 to 100-digit |
Proportional band | 0.1 to 999.9?/?(0.1 to 999.9%) |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | Relay output, SSR drive output: 0.1 to 120.0 sec Current output or SSR drive output selectable: 1.0 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50?, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 2kV) |
Weight | Approx. 150g(approx. 105g) |
•“S” represents SSR drive output support models which SSRP function (standard ON/OFF control, cycle control, phase control) are available. “C” represents selectable current and SSR drive output support models.
?Select “R” or “C” type in case of using heating&cooling control and “N” type in case of using standard control.
?CT input of TK4N is available only for the standard model which has alarm output 1.
?Display accuracy:
?At room temperature (23?±5?)
• Thermocouple K, J, T, N, E type, below -100?/Thermocouple L, U, PL? type, RTD Cu50?, DPt50?: (PV ±0.3% or ±2?, select the higher one) ±1-digit
• Thermocouple C, G, R, S type, below 200?: (PV ±0.3% or ±3?, select the higher one) ±1-digit
• Thermocouple B type, below 400?: there is no accuracy standards.
?Out of room temperature range
• RTD Cu50?, DPt50?: (PV ±0.5% or ±3?, select the higher one) ±1-digit
• Thermocouple R, S, B, C, G type: (PV ±0.5% or ±5?, select the higher one) ±1-digit
• Others, Below -100?: within ±5?
In case of TK4SP Series, ±1? will be added to the degree standard.
?The weight includes packaging. The weight in parenthesis is for unit only.
?Environment resistance is rated at no freezing or condensation.
Temperature Controller | |
Type | High Accuracy |
Power Supply | 110 – 220 VAC |
Dimensions | 48 x 48 mm |
Control Output | Current output (DC4- 20 mA)+SSR voltage output |
Alarm Output | Alarm1+PV transmission |